Fluke 355 – True RMS AC Clamp Ammeter

Brand Fluke
Model Type

Fluke 355

Description

Fluke 355 – True RMS AC Clamp Ammeter

It is a durable and reliable device designed for high current and voltage measurements. Thanks to TrueRMS technology, it provides precise and accurate measurements in demanding industrial applications.

  • TrueRMS measurement technology:It provides accurate and reliable results in AC current and voltage measurements.

  • Large measuring capacity:

    • AC/DC Current Measurement:up to 2000 A

    • AC/DC Voltage Measurement:up to 1000 V

    • Resistance Measurement:up to 400 kΩ

  • Frequency Measurement:It can measure frequencies between 5 Hz and 1 kHz.

  • Continuity Test:It provides the opportunity to quickly check circuit continuity.

  • Wide jaw opening:Provides easy use on large cables and conductors.

  • Compact and robust design:Durable construction for harsh industrial environments.

  • Big screen:It makes it possible to easily read the measurement results.

  • Compliant with CAT IV 600 V and CAT III 1000 V safety standardsIt was produced as.

Set Content:

  • Fluke 355 TrueRMS AC Clamp Ammeter

  • Hardened Test Leads

  • Carrying Bag

  • User Guide

Fluke 355 provides a professional solution for high current and voltage measurements. With its reliable performance and durable structure, it is an indispensable tool for technicians working in industrial applications.

Feature

Value

DC and AC Current Measurement(10 Hz – 100 Hz)

December:40 A / 400 A / 2000 A / 1400 AC RMS
Resolution:10 mA / 100 mA / 1 A
Sensibility:1.5% rdg 15 digits
1.5% rdg 5 digits
Inrush Trigger Level:0.50 A / 5.0 A / 5 A
Hz Filter Off Trigger Level:2.50 A / 2.5 A / 8 A
Hz Filter On Trigger Level:0.50 A / 2.5 A / 8 A

Crest Factor(50/60Hz)

December:40 A / 400 A / 2000 A / 1400 AC RMS
Crest Factor:
2 @ 33 A, 2.4 @ 27 A
2 @ 330 A, 2.4 @ 270 A
2 @ 1000 A, 2.4 @ 833 A

AC Current Measurement(100.1 Hz – 1 kHz)

December:40 A / 400 A / 2000 A / 1400 AC RMS
Resolution:10 mA / 100 mA / 1 A
Sensibility:3.5% rdg 15 digits
3.5% rdg 5 digits
Inrush Trigger Level:0.50 A / 5.0 A / 5 A
Hz Filter Off Trigger Level:2.50 A / 2.5 A / 8 A
Hz Filter On Trigger Level:0.50 A / 2.5 A / 8 A

DC and AC Voltage Measurement(10 Hz – 100 Hz)

December:4 V / 40 V / 400 V / 600 V AC RMS / 1000 VDC
Resolution:1mV / 10mV / 100mV / 1V
Sensibility:%1 rdg 10 digits
%1 rdg 5 digits
Hz Filter Off Trigger Level:0.25V/6V
Hz Filter On Trigger Level:0.25V/6V

AC Voltage Measurement(100.1 Hz – 1 kHz)

December:4V / 40V / 400V / 600V AC RMS
Resolution:1mV / 10mV / 100mV / 1V
Sensibility:3% rdg 10 digits
3% rdg 5 digits
Hz Filter Off Trigger Level:0.050V / 0.25V / 6V
Hz Filter On Trigger Level:0.050V / 0.25V / 6V

Resistance Measurement

December:4 kΩ / 40 kΩ / 400 kΩ
Resolution:0.1Ω / 1Ω / 10Ω / 100Ω
Sensibility:1.5% 5 digits
Continuity Note:open at ≤ 30 Ω, closed at ≥ 100 Ω

Frequency Measurement

Measurement Range:5.0 Hz – 1 kHz
Resolution:0.1 Hz (15 Hz – 399.9 Hz); 1 Hz (400 Hz – 1 kHz)
Sensibility:0.2% 2 digits (5.0 Hz – 100 Hz)
0.5% 5 digits (100.1 Hz – 1 kHz)
Trigger Level:See current and voltage tables

Battery

Six 1.5 V AA NEDA 15 A or IEC LR6

Battery Life

100 hours (with typical use, backlight off)

Weight

0.814 kg (1.8 lb)

Jaw Size

58mm (2.28in)

Dimensions

300 x 98 x 52 mm (12 x 3.75 x 2 in)

Security Degree

IEC 61010-2-032, 600V CAT IV, 1000V CAT III

Operating Temperature

32°F – 122°F (0°C – 50°C)

Storage Temperature

-4°F to 140°F (-20°C to 60°C)

Operating Humidity

0% – 95% (without condensation)

Operating Altitude

2000m

Storage Altitude

10,000m

IP Rating

42 (indoor use only)

Drop Test Requirements

1m

EMI, RFI, EMC

FCC part 15, IEC/EN 61326-1:1997 class B
IEC/EN 61326:1997 3 V/m, performance criterion B, EN61325

Temperature Coefficients

Flow:0.1% of reading per °C (outside 22°C – 24°C)
Income:0.1% of reading per °C (outside 22°C – 24°C)