Fluke 374 FC – True RMS Wireless AC/DC Clamp Meter

Brand Fluke
Model Type

Fluke 374 FC

Description

Fluke 374 FC – True RMS Wireless AC/DC Clamp Meter

It is a device with high performance and wireless connection features designed for AC and DC current measurements in electrical systems. Thanks to Fluke Connect technology, it offers the opportunity to wirelessly transfer and analyze measurement data to mobile devices.

  • AC/DC Current Measurement:It can make precise measurements up to 600 A.

  • AC/DC Voltage Measurement:It provides accurate measurement up to 1000 V.

  • Resistance Measurement:It can measure resistance up to 6000 Ω.

  • TrueRMS technology:Provides accurate measurement even with fluctuating AC signals.

  • Fluke Connect feature:It offers the opportunity to transfer and analyze data to mobile devices via Bluetooth.

  • Optional iFlex current probe:Provides extended measurement capacity up to 2500 A.

  • Big screen:Backlight feature allows easy reading of measurement results even in dark environments.

  • Compliant with CAT IV 600 V / CAT III 1000 V safety standardsIt was produced as.

Set Content:

  • Fluke 374 FC True RMS Wireless AC/DC Clamp Meter

  • Hardened Test Leads

  • Carrying Bag

  • User Guide

The Fluke 374 FC is the perfect tool for technicians working in both industrial and commercial applications. Thanks to its wireless connection features and wide measurement capacity, it helps to make fast and accurate diagnosis in electrical systems.

Feature

Value

AC Current (Through Jaw)

Range: 600.0 A
Resolution: 0.1A
Accuracy: 2% ±5 steps (10 – 100 Hz), 2.5% ±5 steps (100 – 500 Hz)
Crest Factor (50/60 Hz): 2.5 @ 600 A

AC Current Through Tunnel Current Test Probe

Range: 2500 A
Resolution: 0.1 A (0 – 600 A), 1 A (6A)
Accuracy: 2% ±5 steps (5 – 500 Hz)
Crest Factor: 2.5 @ 2500 A

DC Current

Range: 600.0 A
Resolution: 0.1A
Precision: 2% ±5 digits

AC Voltage

Range: 600.0V
Resolution: 0.1V
Accuracy: 1.5% ±5 digits (20 – 500 Hz)

DC Voltage

Range: 600.0V
Resolution: 0.1V
Precision: 1% ±5 digits

Capacitance

Range: 1000 µF
Resolution: 0.1 µF (100 µF), 1 µF (1000 µF)
Precision: 1% ±5 digits

Mechanical Properties

Size: 246mm x 83mm x 43mm
Weight: 318g
Jaw Opening: 14 mm
Tunnel Current Probe Diameter: 75 mm
Tunnel Current Probe Cable Length: 2 m

Media Features

Operating Temperature: -10 °C – 50 °C
Storage Temperature: -40 °C – 80 °C
Operating Humidity: 90% RH (10 °C – 30 °C), 75% RH (30 °C – 40 °C), 45% RH (40 °C – 50 °C)
Operating Altitude: 3000 meters
Storage Altitude: 12,000 meters

EMI, EMC

EN 61326-1:2006

Temperature Coefficients

Add 0.1% x specified precision for each °C above 20 °C or below 10 °C

Security Features

CAN/CSA-C22.2 No. 61010-1-04
ANSI/UL 61010-1:2001
ANSI/ISA-61010-1 (82.02.01):2004
EN/IEC 61010-1:2001
EN/IEC 61010-2-32:2007
EN/IEC 61010-031:2000/A1:2008
CAT III 1000V, CAT IV 600V
Pollution Degree 2

Batteries

2 AA, NEDA 15A, IEC LR6