Fluke 393 FC CAT III 1500 V Clamp Meter

Brand Fluke
Model Type

393 FC CAT III

Description

Fluke 393 FC CAT III 1500 V Clamp Meter

It is a compact and durable measuring device designed especially for solar energy systems and high voltage applications. Compliant with the CAT III 1500 V safety standard, this clamp meter provides reliable and precise DC voltage measurement up to 1500 V. It can also make accurate AC measurements with True RMS technology. Thanks to the Fluke Connect feature, you can wirelessly transfer and analyze measurement data to mobile devices.

  • CAT III 1500 V Safety Standard:Provides safe use in high voltage applications.

  • DC Voltage Measurement:It can make precise measurements up to 1500 V.

  • AC/DC Current Measurement:It makes accurate and reliable measurements up to 1000 A.

  • True RMS Technology:Provides accurate measurement even with fluctuating AC signals.

  • Resistance Measurement:It can measure resistance up to 500 kΩ.

  • iFlex Current Probe:It offers the opportunity to measure in narrow spaces with the optional probe.

  • Fluke Connect Feature:It provides ease of analysis and reporting by transferring data to mobile devices via Bluetooth.

  • Phase Sequence Test:Ability to quickly determine phase sequence in three-phase systems.

  • Large and illuminated display:Backlight feature for easy reading in dark environments.

  • Durability:Design suitable for harsh working conditions with IP54 protection class.

Set Content:

  • Fluke 393 FC CAT III 1500 V Clamp Meter

  • iFlex Current Probe

  • Hardened Test Leads

  • Carrying Bag

  • User Guide

Fluke 393 FC is the ideal solution for professionals who want to make safe, fast and accurate measurements, especially in solar energy systems, high voltage applications and industrial electrical systems. It offers superior features in terms of both security and performance.

Feature

Value

mV DC

December:500.0mV
Resolution:0.1mV
Sensibility:1% ±5 digits

Amperage Frequency (With Chin)

December:5.0 Hz – 500.0 Hz
Resolution:0.1Hz
Sensibility:0.5% ±5 digits
Trigger Level:
– 5 Hz – 10 Hz: ≥10 A
– 10 Hz – 100 Hz: ≥5 A
– 100 Hz – 500 Hz: ≥10 A

Amperage Frequency (with Flexible Current Probe)

December:5.0 Hz – 500.0 Hz
Resolution:0.1Hz
Sensibility:0.5% ±5 digits
Trigger Level:
– 5 Hz – 20 Hz: ≥25 A
– 20 Hz – 100 Hz: ≥20 A
– 100 Hz – 500 Hz: ≥25 A

Voltage Frequency

December:5.0 Hz – 200.0 Hz
Resolution:0.1Hz
Sensibility:0.5% ±5 digits
Trigger Level:
– 5 Hz – 20 Hz: ≥5 V
– 20 Hz – 100 Hz: ≥5 V

DC Power

December:600.0 V (300.0 V DC range)
Resolution:0.1V
Sensibility:1% ±5 digits

Resistance

December:60.00 kΩ / 6000 Ω / 600.0 Ω
Resolution:0.1 Ω (≤600.0 Ω), 1 Ω (≤6000 Ω), 10 Ω (≤60.00 kΩ)
Sensibility:1% ±5 digits

Capacitance

December:1000µF
Resolution:0.1 µF (≤100.0 µF), 1 µF (≤1000 µF)
Sensibility:1% ±4 digits

Mechanical Dimensions

274mm x 86mm x 47mm

Weight (including batteries)

463g

Jaw Opening

34mm

Flexible Current Probe Diameter

7.5mm

Flexible Current Probe Cable Length

1.8m

Operating Temperature

-10 °C to 50 °C

Storage Temperature

-40 °C to 60 °C

Working Height

2000m

Storage Height

12,000m

Ingress Protection Degree

IEC 60529: IP54

Electromagnetic Compatibility

IEC 61326-1: Portable Electromagnetic Media