Fluke 566 Infrared and Contact Thermometer -40°/ 650°

Brand Fluke
Model Type

Fluke 566

Description

Fluke 566 Infrared and Contact Thermometer -40°/ 650°

It is a professional device with a wide temperature range that can measure both non-contact and contact temperature. Capable of measuring between -40°C and 650°C, this thermometer offers a wide range of applications, from maintenance of industrial equipment to HVAC systems. Thanks to its ergonomic design and durable structure, it provides reliable performance in harsh working conditions.

  • Non-contact Infrared Measurement:It makes remote, fast and precise temperature measurements.

  • Contact Measurement:Possibility to directly measure surface temperatures with optional probe.

  • Wide Temperature Range:It can measure between -40°C and 650°C.

  • Dot Rate:It provides precise measurement on small targets with 30:1 optical resolution.

  • Adjustable Emissivity:Adjustable emissivity according to different surface materials provides more accurate measurement.

  • Fast Response Time:It detects temperature changes instantly.

  • Backlit LCD Display:Easy reading in low light environments.

  • Easy to Use:Ergonomic design for one-handed use.

  • Durability:Robust construction suitable for harsh industrial environments.

  • Last Measurement Memory:It provides convenience with its feature of storing measurement results.

  • Alarm Feature:It gives a warning when the specified temperature ranges are exceeded.

Fluke 566 Infrared Contact multi-purpose Thermometer comes with optional probe, user manual and battery. Thanks to its high accuracy, wide temperature range and practical use, it is a reliable measuring device for professional users. It is an ideal solution especially for industrial maintenance, HVAC systems and energy saving works.

Feature

Value

Infrared Temperature Range

-40°C to 650°C (-40°F to 1202°F)

Infrared Accuracy

< 0°C (32°F): ±(1.0°C (±2.0°F) 0.1°/1°C or °F);
> 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater

Screen Resolution

0.1°C / 0.1°F

Infrared Spectral Response

8 µm to 14 µm

Infrared Response Time

< 500ms

Thermocouple Type-K Input Temperature Range

-270°C to 1372°C (-454°F to 2501°F)

Thermocouple Type-K Input Accuracy

-270°C to -40°C: ±(1°C 0.2°/1°C) (-454°F to -40°F: ±(2°F 0.2°/1°F))
-40°C to 1372°C: ±1% or ±1°C (-40°F to 2501°F: ±1% or ±2°F), whichever is greater

Distance Dot Rate

30:1

Laser Pointer

Single point laser < 1 mw output, Class 2 (II), 630 nm to 670 nm

Minimum Dot Size

19mm (0.75in)

Emissivity Adjustment

Adjustable from 0.10 to 1.00 in 0.01 steps via built-in material table or digitally

Data Storage (Date/Time Stamp)

20 dots

PC Interface and Cable

None

High/Low Alarms

Audio and two-color visual

Min/Max/Avg/Difference

Yes

Screen

98 x 96 pixel dot matrix, function menus

Backlight

Two levels, normal and extra bright

Trigger Lock

Yes

Degree/Degree Fahrenheit Changeable

Yes

Strength

2 AA/LR6 Batteries

Battery Life

In continuous use:
Laser and backlight on, 12 hours; laser and backlight off, 100 hours

Operating Temperature

0°C to 50°C (32°F to 122°F)

Storage Temperature

-20°C to 60°C (-40°F to 140°F)

Thermocouple Type-K Bead Range

-40°C to 260°C (-40°F to 500°F)

Thermocouple Type-K Bead Accuracy

0°C to 260°C: ±1.1°C (2.0°F)
-40°C to 0°C: ±1.1°C (2.0°F)