Fluke 773 Miliamper Proses Pensmetre
| Brand | Fluke |
|---|---|
| Model Type |
Fluke 773 |
Fluke 773 Milliamp Process Calibrator
A device with advanced features such as measurement, simulation, and loop power supply of 4-20mA signals in process control systems. The Fluke 773 offers professional solutions in the field and laboratory environments with the ability to measure current without breaking the circuit, signal generation, and independent testing of transmitters. With its advanced features, it provides time savings and high precision for maintenance technicians and engineers.
-
Current Measurement Range: 0-20.99 mA DC for precise measurement.
-
Accuracy: High accuracy with a ±0.2 accuracy rate.
-
Resolution: Detailed measurement with 0.01 mA resolution.
-
Measurement Without Breaking the Circuit: Time-saving by measuring current without opening the circuit.
-
Loop Power Supply: Providing 24V loop power to enable testing of transmitters.
-
Current Simulation: Simulation of 4-20 mA loop signals.
-
Signal Generation: Producing precise mA signals for analog inputs.
-
Current Measurement and Source: Simultaneously providing both measurement and signal source features.
-
LED Light: Integrated LED light for easily finding connection points in dark environments.
-
Auto Shutdown: Auto shutdown feature for energy savings.
-
Low Power Consumption: Long battery life for long-term field use.
-
Compact and Lightweight Design: Ergonomic structure for easy portability.
-
Handheld Portability: Compact design for one-handed use.
Applications:
-
Process Control Systems: Measurement, simulation, and control of 4-20 mA signals.
-
Transmitter Testing: Verification, calibration, and independent testing of transmitters.
-
PLC and Analog Input Testing: Testing of PLC analog inputs and outputs.
-
Field Maintenance: Quick and easy current measurement for field maintenance operations.
-
Energy Management: Monitoring current signals and achieving energy savings.
The Fluke 773, unlike other mA process calibrators, has features such as signal generation and loop power supply. This allows independent testing of transmitters and analog inputs. The capability to provide both measurement and signal source simultaneously makes the device an indispensable tool for maintenance technicians and engineers.
The Fluke 773 Milliamp Process Calibrator comes with a user manual, carrying case, and long-life battery. With its advanced features, it optimizes processes in field and laboratory environments and delivers reliable results.
|
Feature |
Details |
|---|---|
|
Conductor Size |
0.177″ or 4.5 mm maximum |
|
Operating Temperature |
-10 to 50°C |
|
Storage Temperature |
-25 to 60°C |
|
Operating Humidity |
< 90% @ <30°C, < 75% @ 30 to 55°C |
|
Operating Altitude |
0 to 2000 m |
|
IP Protection Class |
IP 40 |
|
Dimensions |
44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in) |
|
Weight |
410 g (14.4 oz) |
|
Vibration |
Random 2 g, 5 to 500 Hz |
|
Shock |
1 m drop test (chin included) |
|
EMI/RFI |
Complies with EN61326-1 |
|
Temperature Coefficient |
0.01% per °C (< 18°C or > 28°C) |
|
Power |
(4) AA 1.5 V Alkaline, IEC LR6, 12 hours in a 500 ohm load at mA source |
Functional Features
|
Function |
Resolution / Range |
Accuracy |
|---|---|---|
|
mA Measurement (With Clamp) – Battery Life |
0 to 20.99 mA |
%0.2 + 5 digits |
|
|
21.0 mA to 100.0 mA |
%1 + 5 digits |
|
mA Measurement (With Test Leads) |
0 to 24.00 mA |
%0.2 + 2 digits |
|
mA Source |
0 to 24.00 mA (maximum output: 24 mA, 1,000 ohm) |
%0.2 + 2 digits |
|
mA Simulation |
0 to 24.00 mA (maximum voltage: 50 V DC) |
%0.2 + 2 digits |
|
Voltage Source |
0 to 10.00 V DC (maximum output current: 2 mA) |
%0.2 + 2 digits |
|
Voltage Measurement |
0 to 30.00 V DC |
%0.2 + 2 digits |
Related products
Çift Akülü 12 Köşe 360° 58Vf Otomatik Hizalamalı Lazer Metre
In stock
| Brand | Bosch Plus |
|---|---|
| Model Type |
EEA302 |